All Categories
  

Pipetting

Biosystem Company is devoted to manufacturing of high quality products used in laboratory industry. Biosystem has invested in R&D, Production, Technology, Automation & Quality control bring together the requirements of both international &....

Price : Rs 0.00

20-April-2019

Compnay Information

Member Since : 2012 | Normal Member

105, Sahakar Industrial Estate, Navghar Road, Vasai (E), Thane (Mumbai)-401 210., Palghar, Maharashtra, India

93231 64173

www.micropipette.in

Accepted Payment Currency by you :
USD
Accepted Delivery Terms by you :
FOB,CIF,FAS,FCA,DDP
Payment Method you accept :
T/T,L/C,CC,Paypal,cash/cheque
Average Lead Time / Day(s) :
6 Days
Nearest Port :
Mumbai & Jawaharlal Nehru Port
Accept Escrow Services :
Yes

Service Description


Pipetting

Following are the complete details of correct pipetting method.

Setting The Volume

HOW TO SET THE VOLUME

  • Hold the micropipette horizontally.
  • If you want to increase the volume move the plunger clockwise with your thumb, and to decrease the volume move it anti- clockwise.

 

Capture

Pipetting

HOW TO DO PIPETTING

  • Set the desired volume.
  • Depress the operating button to the first stop.
  • Insert the micro tips of selected volume range.
  • Push out the used tip by pressing the tip ejector.
  • Release the plunger button to the ready position.
  • Withdraw the tip from the liquid touching it against the inner wall of the test-tube to remove excess liquid.
  • Withdraw the tip from the liquid touching it against the inner wall of the test-tube to remove excess liquid.
  • Dip the tip under the surface of the liquid in the test-tube Approximately 1 cm deep, & slowly release the plunger button.

 

Capture1

Pipetting Technique

Forward Pipetting

  • Press the operating button to the first stop.
  • Dip the tip attached to the pipette to a depth of about 1 CM, and slowly release the operating button withdraw the tip from the liquid touching it against the inner wall of the reservoir to remove excess liquid.
  • Dispense the liquid into the receiving vessel by gently pressing the operating button to the first stop. After one second, press down the operating button to the second stop. This action will empty the tip. Remove the tip from the vessel sliding it along the wall of the vessel.
  • Release the operating button to the ready position.

 

forward_pipeting

Reverse Pipetting

  • Press the operating button to the first stop.
  • Dip the tip attached to the pipette to a depth of about 1cm., and slowly release the operating button withdraw the tip from the liquid touching it against the inner wall of the reservoir to remove excess liquid.
  • Dispense the liquid into the receiving vessel by pressing the operating button gently and steadily to the first stop. Hold the button in the position. Some liquid will remain in the tip position this shouldn’t be dispensed.
  • The liquid remaining in the tip can be pipette back into the original solution or thrown away with the tip.
  • Release the operating button to the ready position.

Biosystem Company is devoted to manufacturing of high quality products used in laboratory industry. Biosystem has invested in R&D, Production, Technology, Automation & Quality control bring together the requirements of both international & domestic market.

Since 10 years we at Biosystem engraved the philosophy to produce world class quality products at affordable yet innovative. Our hard work in the filed of R&D had given us the position to generate latest trend & user friendly products range having latest production technology & extensive quality control at every stage starting with primary designing to inventory management system. At same time it is our constant effort to meet highest standard in Accuracy & Precision.

In a short span we have achieved ISO 9001:2008 from, CE Mark from (TUV Rheinland ), Design patents approval from ( Govt. of India ) & calibration laboratory follow the guidelines of ISO 2005 (calibration & testing).

We are able to create strong & capable dealer network throughout India. We also took great efforts to put our presence in most sensitive yet crucial area of calibration micropipette of other brand through Biosystem laboratories. Our Service & Calibration programs in another step towards building long relationship.

Our Products

MICROPIPETTE

products_micropipette

 

OEM

products_OEM

 

LABWARE

products_labware

 

INSTRUMENTS

products_instruments

CONTACT INFORMATION

Work Office : 105, Sahakar Industrial Estate,Navghar Road, Vasai (E),
Thane(Mumbai)-401 210.
Landmark : Opp. Tirupati Shopping Arcade. 2-3 mins walk from Vasai Station.
State : Maharashtra
Country : India

 

QUICK CONTACT

  • Tel. :
+91-0250-2393979
  • Mob :
+91 93231 64173 / +91 93203 64173
  • E-Mail :
biosystem2007@yahoo.com / biosystem2002@gmail.com

Images


Pipetting
Pipetting
Pipetting
Pipetting

Videos


Images
Pipetting
Pipetting
Pipetting
Pipetting
 
Videos


Please Login To Give The FeedBack.

Average user rating

0 / 5

Rating breakdow

5
80% Complete (danger)
0
4
80% Complete (danger)
0
3
80% Complete (danger)
0
2
80% Complete (danger)
0
1
80% Complete (danger)
0

Send your message to this supplier

Leave a reply Your email address will not be published.

Enter text

Verification Code:
Premium Related Service

BIOSYSTEM - MAINTENANCE

Price at : Rs 0.00

TROUBLE SHOOTING

Price at : Rs 0.00

BIO STAND

Price at : Rs 0.00

BIO ULTIMA

Price at : Rs 0.00

BIO ADVANCE

Price at : Rs 0.00