All Categories
  

BIOSYSTEM - MAINTENANCE

Biosystem Company is devoted to manufacturing of high quality products used in laboratory industry. Biosystem has invested in R&D, Production, Technology, Automation & Quality control bring together the requirements of both international &....

Price : Rs 0.00

20-April-2019

Compnay Information

Member Since : 2012 | Normal Member

105, Sahakar Industrial Estate, Navghar Road, Vasai (E), Thane (Mumbai)-401 210., Palghar, Maharashtra, India

93231 64173

www.micropipette.in

Accepted Payment Currency by you :
USD
Accepted Delivery Terms by you :
FOB,CIF,FAS,FCA,DDP
Payment Method you accept :
T/T,L/C,CC,Paypal,cash/cheque
Average Lead Time / Day(s) :
6 Days
Nearest Port :
Mumbai & Jawaharlal Nehru Port
Accept Escrow Services :
Yes

Service Description


MAINTENANCE

To maintain the durability of Biosystem’s pipettes proper “Care and Maintenance” is required.

SHORT-TERM MAINTENANCE

  • Hold the micropipette horizontally.
  • If you want to increase the volume move the plunger clockwise with your thumb, and to decrease the volume move it anti- clockwise.

Note: The calibration has to be checked after cleaning the pipette.

 

maintenance

 

LONG-TERM MAINTENANCE

If the micropipette is used daily, it is recommended to check the calibration every three months.

AUTOCLAVING

  • Biosystem (Color) model pipettes are partially autoclaved (i.e. only the “Tip Cone Module”) at 121°C (248°F) for 20 minutes.
  • After autoclaving, the autoclaved part must be cooled down and left to dry overnight before use.

Note : The calibration has to be checked after every autoclaving.

 

 

Decontamination Procedure

maintenance_01

  • 1. Remove the tip ejector by holding down the ejector and inserting the tool supplied to relese the locking mechanism carefully,release the “tip ejector” and “shaft”.

maintenance_02

  • 2. Slowly turn anti-clockwise “tip cone”.

maintenance_03

  • 3. Remove the tip ejector by holding down the ejector and inserting the tool supplied to relese the locking mechanism carefully,release the “tip ejector” and “shaft”.

maintenance_03

  • 4. Placethe”tipcone”,”tipejector”,”shaft”,”pistone”,”o-ring” and “spring” intothe beaker containing 70% ethyle alchole
    and keave for atleast 30mints.
  • 5. After performing the above procedure remove the components from the beaker and rinse them with distilled water,then dry preferably with warm air,for atleast an hour.
  • 6. Re-grease the piston as described in tje instruction manu.

Note: Every 6 month when you performing Decontimination procedure kindly check ‘ 0 ‘ -ring and if possible kinly replaced if  necessary.The calibration has to be checked after cleaning the pipette.

Biosystem Company is devoted to manufacturing of high quality products used in laboratory industry. Biosystem has invested in R&D, Production, Technology, Automation & Quality control bring together the requirements of both international & domestic market.

Since 10 years we at Biosystem engraved the philosophy to produce world class quality products at affordable yet innovative. Our hard work in the filed of R&D had given us the position to generate latest trend & user friendly products range having latest production technology & extensive quality control at every stage starting with primary designing to inventory management system. At same time it is our constant effort to meet highest standard in Accuracy & Precision.

In a short span we have achieved ISO 9001:2008 from, CE Mark from (TUV Rheinland ), Design patents approval from ( Govt. of India ) & calibration laboratory follow the guidelines of ISO 2005 (calibration & testing).

We are able to create strong & capable dealer network throughout India. We also took great efforts to put our presence in most sensitive yet crucial area of calibration micropipette of other brand through Biosystem laboratories. Our Service & Calibration programs in another step towards building long relationship.

CONTACT INFORMATION

Work Office : 105, Sahakar Industrial Estate,Navghar Road, Vasai (E),
Thane-401 210.
State : Maharashtra
Country : India
Landmark : Opp. Tirupati Shopping Arcade. 2-3 mins walk from Vasai Station.

 

QUICK CONTACT

  • Mob :
+91 93231 64173 / +91 93203 64173
  • E-Mail :

biosystem2007@yahoo.com / biosystem2002@gmail.com

Images


BIOSYSTEM - MAINTENANCE

Videos


Images
BIOSYSTEM - MAINTENANCE
 
Videos


Please Login To Give The FeedBack.

Average user rating

0 / 5

Rating breakdow

5
80% Complete (danger)
0
4
80% Complete (danger)
0
3
80% Complete (danger)
0
2
80% Complete (danger)
0
1
80% Complete (danger)
0

Send your message to this supplier

Leave a reply Your email address will not be published.

Enter text

Verification Code:
Premium Related Service

TROUBLE SHOOTING

Price at : Rs 0.00

Pipetting

Price at : Rs 0.00

BIO STAND

Price at : Rs 0.00

BIO ULTIMA

Price at : Rs 0.00

BIO ADVANCE

Price at : Rs 0.00